AWM2
MICROMODULE |
|
|
|
MicroModules are designed to fit in the rear of junction boxes, behind any
installed switch.The AWM2
MicroModule is an extremely small X10 Transmitter for 2 addresses with
built-in appliance module. The AWM2 connects up to 2 momentary or
maintained switches by wire leads. |
|
|
External switch 1 (connected to the brown and blue wire) controls the
relay and transmits ON/OFF X-10 command for the configured address. Switch
2 (connected to the red and blue wire) only transmits an ON/OFF command
for the configured address plus one. MicroModules use 2 way X-10
communication. Eon3 MicroModules are designed to fit in the rear of
junction boxes, behind any installed switch or outlet |
| |
|
|
Features |
|
| |
|
- Extreme small size (46x46mm and only
16 mm thick)
- Built-in appliance module with 16A
rating
- Relay holds last state on power loss
- Low noise relay
- Two-way X-10 communication
- Able to change internal ON/OFF state
by global commands like ALL LIGHTS ON and ALL UNITS OFF to stay in
"sync" with modules to which it is configured
- HouseCode, UnitCode and settings can
be simply programmed with every X-10 compatible controller (e.g. Eon3 8
in 1 in combination with TM13 transceiver)
- Improved S/N ratio for reliable X-10
communication
Power/Status/Configuration LED
-
|
 |
|
|
|
|
Applications |
|
|
|
- Remote ON/OFF control of electrical
loads
- Provides powerline carrier control to
existing light switches
- Transforms conventional switches into
an X-10 transmitter
- Full control of all your X-10 modules
by conventional switches
- Choose your own brand, design and
color for switches and wall sockets
- Place X-10 modules out of sight
- Turn every existing wall socket into
an X-10 controlled wall socket
- Ideal for installation into light
fixtures, home appliances and other limited areas
- Install two way switches without any
additional wiring between switches (Eon3 MicroModules transmit their
status to other MicroModules through the power line).
- Use a conventional switch on a fixed
location to execute Macro's
|
|
Technical Specifications |
|
| Power
|
|
| Supply Voltage |
230VAC, +10%/-15% |
| Frequency |
50Hz |
| Supply current |
Less than 50mA |
|
|
|
|
|
Signal |
|
| Signal input |
X-10 PowerLine Carrier,
sensitive to 5OmV |
| Signal output |
X-10 PowerLine Carrier,
5 Vpp @ 5 Ohms |
| Relay |
16 A |
|
|
|
|
3 phase use
The AWM2 transmits signals for use on 1 phase only. You should use the
CAT3000 repeater to be able to receive the commands of the AWM2 on other
phases. The AWM2 does receive commands from standard Eon3 X10 transmitters
on different phases.Two wall
switch inputs (dry contact): Three 120mm, 0.33mm2
|
flying leads: |
Switch 1: Brown (controls the relay)
Switch 2: Red (controls next sequential address)
Common: Blue |
|
|
Programming
Can be programmed by every Eon3 X-10 compatible controller.
Can also be programmed by special Eon3 PRU256 programmer/X10 log |
|
|
Mechanical requirements
Power
Screw terminals (2x)
L - Will handle up to 2.5mm2 solid copper wire
N - Will handle up to 2.5mm2 solid popper wire
Load Output |
|
Screw terminals
(2x)
L - Will handle up to 2.5mm2 solid copper wire
N2 - Will handle up to 2.5mm2 solid copper wire
Enclosure Dimensions 46 x 46 x 16 mm
Weight 34 grams
Mounting Sized for mounting of 75mm dia x 50mm deep electrical junction
box, or other limited areas |
|
|
Environmental Requirements
Operating Temperature Range -10 to +40 degrees C
Storage Temperature Range -20 to +70 degrees C
Humidity Range 10 to 95% non condensing
Approvals NEN-EN-IEC 60669-2-1, NEN-EN-IEC 60669-2-2, CE
Specifications may change without notice to improve product performance |
|